latest circuit and explanation of Basic UPS Power Supply

Circuit : Andy Collinson
Email: anc@mitedu.freeserve.co.uk

Description
This circuit is a simple form of the commercial UPS, the circuit provides a constant regulated 5 Volt output and an unregulated 12 Volt supply. In the event of electrical supply line failure the battery takes over, with no spikes on the regulated supply.

UPS


Notes:
This circuit can be adapted for other regulated and unregulated voltages by using different regulators and batteries. For a 15 Volt regulated supply use two 12 Volt batteries in series and a 7815 regulator. There is a lot of flexibility in this circuit.
TR1 has a primary matched to the local electrical supply which is 240 Volts in the UK. The secondary winding should be rated at least 12 Volts at 2 amp, but can be higher, for example 15 Volts. FS1 is a slow blow type and protects against short circuits on the output, or indeed a faulty cell in a rechargeable battery. LED 1 will light ONLY when the electricity supply is present, with a power failure the LED will go out and output voltage is maintained by the battery. The circuit below simulates a working circuit with mains power applied:

mains

Between terminals VP1 and VP3 the nominal unregulated supply is available and a 5 Volt regulated supply between VP1 and VP2. Resistor R1 and D1 are the charging path for battery B1. D1 and D3 prevent LED1 being illuminated under power fail conditions. The battery is designed to be trickle charged, charging current defined as :-

(VP5 - 0.6 ) / R1
where VP5 is the unregulated DC power supply voltage.


D2 must be included in the circuit, without D2 the battery would charge from the full supply voltage without current limit, which would cause damage and overheating of some rechargeable batteries. An electrical power outage is simulated below:

power


Note that in all cases the 5 Volt regulated supply is maintained constantly, whilst the unregulated supply will vary a few volts.

Standby Capacity
The ability to maintain the regulated supply with no electrical supply depends on the load taken from the UPS and also the Ampere hour capacity of the battery. If you were using a 7A/h 12 Volt battery and load from the 5 Volt regulator was 0.5 Amp (and no load from the unregulated supply) then the regulated supply would be maintained for around 14 hours. Greater A/h capacity batteries would provide a longer standby time, and vice versa. 
Read More..

Wednesday, October 8, 2014

Low Cost Fire Alarm Circuit and explanation Using Transistor

Transistor BC177 (Q1) is used as the fire sensor here. When the temperature increases the leakage current of this transistor also increases.The circuit is designed so that when there is an increase in the leakage current of Q1, transistor Q2 will get biased. As a result when there is a fire breakout the transistor Q2 will be on. The emitter of Q2 (BC 108)is connected to the base of Q3(AC 128). So when Q2 is ON Q3 will be also ON. The transistor Q3 drives the relay which is used to drive the load ie,light,bell,horn etc as an indication of the fire. The diode D1 is used as a free wheeling diode to protect it from back EMF generated when relay is switched.


Notes:
  • The Preset R1 can be used to desired temperature level for setting the alarm ON.
  • This is not a latching alarm,ie; when the temperature in the vicinity of the sensor decreases below the set point the alarm stops.
  • The circuit can be powered using a 9V battery or a 9V battery eliminator.
  • All capacitors are electrolytic and must be rated at least 10V.
  • The load can be connected through the C,NC,NC points of the relay according to your need.
  • The calibration can be done using a soldering iron,and a thermo meter. Switch ON the power supply.Keep the tip of soldering iron near to the Q1.Same time also keep the thermometer close to it.When the temperature reaches your desired value adjust R1 so that relay gets ON.
Read More..

LM1877 bassed Audio power amplifier circuit and explanation

Using the LM1877 monolithic dual power amplifier can be designed a very simple audio amplifier circuit for small audio applications like portable devices .

This audio amplifier circuit is designed to deliver 2W per channel continuous into 8Ω loads. The LM1877 is designed to operate with a low number of external components, and still provide flexibility for use in stereo phonographs, tape recorders and AM-FM stereo receivers, etc.
Each power amplifier is biased from a common internal regulator to provide high power supply rejection, and output Q point centering. The LM1877 is internally compensated for all gains greater than 10.

This audio amplifier circuit can be powered from a wide input voltage range from 6 volt up to 24 volts .
For this audio power amplifier circuit diagram you must use a 8 ohms speaker .
Read More..

Tuesday, September 23, 2014

Simple Rain Detector circuit and explanation

Heres a simple rain detector circuit. It uses a sensor made of a small piece of etched PC board and a simple SCR circuit to detect rain and sound a buzzer. The SCR could also be used to activate a relay, turn on a lamp, or send a signal to a security system.



Rain Sensor and Alarm
The sensor made of a small piece of PC board etched to the pattern showen in the schematic. The traces should be very close to each other, but never touching. A large spiral pattern would also work. A loud buzzer used as an alarm.

Rain Detector Parts List

R1 = 1K 1/4 W Resistor
R2 = 680 Ohm 1/4 W Resistor
D1 = 1N4001 Silicon Diode
BZ1 = 12V Buzzer
S1 = SPST Switch
SCR1 = C106B1 SCR 106CY
SENSOR = See Notes
MISC = Board, Wire, Case, PC Board (For Sensor) 
Read More..